A window and door RFQ cover sheet is the control page for a pricing package. It tells every bidder what the project includes, which document revisions govern the quote, how base scope and alternates must be returned, and where assumptions or exclusions belong. It does not replace the plans or opening schedule. Its job is to make sure each supplier receives and responds to the same information set.

For a custom home builder, that distinction matters. A detailed plan set can still produce proposals that are difficult to compare when bidders use different revisions, interpret the package boundary differently, or bury exceptions in email. A short, controlled cover sheet gives the estimator one place to define the issue.

What the RFQ cover sheet controls

The cover sheet controls the pricing request—not the final design and not production authorization. It should establish:

  • who issued the RFQ and who should respond;
  • which window and door systems or opening marks are in the requested package;
  • which drawings, elevations, schedules and specifications were issued;
  • which items are base scope, alternates, allowances or TBD;
  • how the supplier should present pricing, assumptions and exclusions;
  • when and where clarification questions must be submitted; and
  • which addenda the bidder has acknowledged.

The architectural team and qualified local project team still resolve project criteria, verify site conditions and approve final production information. A quotation remains a supplier proposal based on the information issued at that time.

1. Identify the project, issue and bidder

Start with a unique RFQ number, issue date and project identifier. Include the project city and state or province because destination and local project requirements can affect scope discussions. Identify the bidder and the person responsible for the response. State the quotation due date and time zone rather than relying on an email timestamp.

If the package has been issued before, label the new issue clearly. Do not silently replace attachments. A bidder should be able to determine whether it is responding to an original RFQ, a revised issue or an addendum.

2. Define the requested supply scope

Describe the package in operational language. Name the included system categories and, where the documents support it, the opening-mark range. Then list known exclusions and unresolved items. Use TBD when the project team has not selected a criterion; do not invite suppliers to guess.

Separate supply scope from local work. Delivery, unloading, storage, installation, perimeter interfaces, field verification and professional review should not be assumed merely because a proposal says “complete package.” Ask the bidder to state what is included and excluded in its written proposal.

3. List the issued documents

Create one row for every file the bidder is expected to use. Record the exact file name, drawing or schedule title, revision, issue date and purpose. If an older file is superseded, say so. This register allows the builder to compare a returned proposal against the correct source set.

Document Revision/date Purpose Status
Architectural plans TBD Opening locations and design context Issued for pricing
Window and door schedule TBD Opening-level quotation inputs Issued for pricing
Finish schedule TBD Finish intent and unresolved selections Issued / TBD
Addendum TBD Clarifications after RFQ issue Acknowledgment required

If the opening schedule is not ready, build it before expecting a comparable package quote. Meruzy's guide to preparing a window and door schedule explains the opening-level fields that belong there.

4. Separate base scope from alternates

Ask every bidder to price the same base condition. Give each alternate a unique ID and a one-sentence description. Require the returned proposal to show whether the alternate adds to, deducts from or replaces part of the base scope. If a decision is not mature enough to price, identify it as TBD instead of disguising it as an allowance.

This structure makes the later comparison more reliable, but it does not guarantee identical proposals. Use a separate scope-by-scope quote comparison after proposals return.

5. State the quotation-return requirements

Tell the bidder what a useful response must contain: package total and requested breakouts; included opening marks and quantities; alternates; assumptions; exclusions; proposed delivery basis; document references; and any commercial or schedule information the bidder is prepared to confirm. Do not insert universal validity periods, payment terms or lead times into a template. Those are project- and supplier-specific written terms.

6. Control questions and addenda

Use one clarification contact and one question deadline. Record answers in a shared clarification log or formal addendum rather than answering different bidders privately. Ask each bidder to acknowledge every addendum in its proposal. A verbal answer should not quietly change the priced scope.

Copyable RFQ cover sheet

Project / location TBD
RFQ number / issue date TBD
Bidder / contact TBD
Quotation due / time zone TBD
Requested package Systems and opening marks included
Known exclusions / TBD items TBD
Issued documents File, revision, date and purpose
Base-scope instruction TBD
Alternates ID, description and requested breakout
Return requirements Pricing, quantities, assumptions, exclusions and proposed terms
Clarification contact / deadline TBD
Addenda acknowledged TBD

Five-minute pre-issue check

  1. Confirm that the RFQ number and issue date are unique.
  2. Confirm that every attachment appears in the document register.
  3. Remove superseded files from the issue package.
  4. Mark unresolved criteria TBD and assign a decision owner.
  5. Confirm that base scope and each alternate are distinguishable.
  6. State the response format and clarification channel.
  7. Save evidence of what was issued to each bidder.

Send one controlled package for pricing

Meruzy manages and coordinates selected manufacturing partners for custom architectural systems. Builders can send current plans, schedules and RFQ information for a free project quotation; proposed product drawings and revisions are also free. There is no minimum project amount. The local project team must verify site conditions and approve final production information.

Request a project quote from the current RFQ package.

Editorial review

Prepared for project education and reviewed for consistency with MERUZY’s current supply-only design, quotation and delivery process. Project-specific requirements are governed by approved documents and the formal order.

Reviewed by: MERUZY Project Coordination Team

Sources and further reading

QUESTIONS & DISCUSSION

Ask a question or add to the discussion

Have a question about this guide? Ask it here. The MERUZY team and other project professionals may respond.

Do not include private project information, addresses, drawings, pricing, order details, phone numbers or email addresses in your public comment.

Your email is used for moderation and is not displayed publicly.

Submissions are reviewed before publication. Please allow time for moderation.

Have a project to review?

Share your plans, rough dimensions, or schedules for a comprehensive DDP estimate and technical review.

Request a Project Quote